• BRILLIANT ILLUMINATION AND CRYSTAL CLEAR RESOLUTION

• TRUE COLOUR REFLECTION AND REGULAR FOCUS ON THE WHOLE IMAGE

• OPTIMAL DEPTH OF FIELD

• STORZ- OLYMPUS- TEKNO / WOLF / ACMI ADAPTERS INCLUDED

• AUTOCLAVABLE; INCL.1 SEALING CAB AND 2 CLEANING BRUSHES

• MADE IN GERMANY

• CE, FDA
• BRILLIANT ILLUMINATION AND CRYSTAL CLEAR RESOLUTION

• TRUE COLOUR REFLECTION AND REGULAR FOCUS ON THE WHOLE IMAGE

• OPTIMAL DEPTH OF FIELD

• STORZ- OLYMPUS- TEKNO / WOLF / ACMI ADAPTERS INCLUDED

• AUTOCLAVABLE; INCL.1 SEALING CAB AND 2 CLEANING BRUSHES

• MADE IN GERMANY

• CE, FDA
Ceramic coatingTest

Choose region:

PSLD Endoscopic System

PSLD Endoscopic System

5.7 mm working channelCeramic coating

Description

 (Percutaneous Stenoscopic Lumbar Decompression)

  • Interlaminar Lumbar stenosis Decompression
  • Central & B/L Lateral Recess
  • Lumbar disc herniation – Interlaminar approach
  • Cervical procedure posterior approach
  • Developed in cooperation with Dr Kangtaek Lim and Dr Gun Choi

Lumbar spinal decompression is performed with a posterior interlaminar approach. A skin incision of app. 8-9mm is made in the interlaminar window. A conical blunt dilator is introduced in the interlaminar window. A working cannula is introduced over the dilator with the beveled opening of the working cannula directed medially towards the ligamentum flavum. Sequential trimming of the Inferior articular process- Superior Lamina, Superior articular process – Inferior lamina is performed with motorised drills & Kerrison rongeurs.

After completion of bony decompression, Ligamentum flavum is removed ipsilaterally and centrally within the bony window created by trimming the facet & lamina, Complete decompression of the thecae sac & ipsilateral traversing root is performed from tip if the Superior articular process to 1/2 of caudal pedicle. For contralateral decompression the base of the spinous process is trimmed with the motorised drill and contralateral bony & soft tissue decompression performed with thinning of the lamina, Trimming the Inferior articular process, Superior articular process, cranial & Caudal lamina dorsal to the thecal sac. Ligamentum flavum is removed to decompress the contralateral traversing root. The entire procedure is performed under endoscopic visual control using the MaxMoreSpine 5.7 mm endoscope.

content starter kit

Article code Product description Qty
1002-TS 004 TOM Endo Stick 5.7 mm working channel 1
1001-DC 010 Dilator 7.9 mm 1
1001-ES 19 Working Sleeve 112 mm / 8.5 mm ID 1
1001-SK 001/H Universal Coated Kerrison Punch Handle 4
1001-SK 002/S Coated Kerrison Punch Shaft, 240 mm / Ø 5 mm down to 2 mm, 40° 2
1001-SK 003/S Coated Kerrison Punch Shaft, 240 mm / Ø 5 mm down to 3 mm, 40° 2
1001-SK 004/S Coated Kerrison Punch Shaft, 240 mm / Ø 5 mm down to 4 mm, 40° 2
1001-SK 005/S Coated Kerrison Punch Shaft, 240 mm / Ø 5 mm down to 5 mm, 40° 2
1001-DI 01 Dissector ø 3.5mm / 245 mm 1
1001-TH 001 Tactile Hook - Small Hook 1
1001-TH 002 Tactile Ball Hook - Big Hook 1
1001-SF 001 Stenosis Grasping forceps 3.0 mm / 250 mm 1
1001-SF 002 Stenosis Grasping forceps 4.0 mm / 250 mm 1
1001-IS 005 Instrument Container Stenosis 1
1001-IS 006 Instrument Tray Stenosis 1

1001 - SSK 1 STENOSIS / INTERLAMINAR
STARTER KIT INCL. 1 ENDOSCOPE

1001 SSK1 stenosis container set
  • 5.7 MM WORKING CHANNEL
  • 113 MM WORKING LENGTH
  • BLACK 10° ANGLED DIRECTION OF VIEW
  • SUCTION/ IRRIGATION CHANNEL;
  • FIRST CLASS COMPACT OBJECTIVES
  • LATEST GENERATION OF ROD LENSES GUARANTEES AN ILLUMINATION WHICH REALLY IS SECOND TO NONE
  • SCRATCH-PROOF SAPHIRE GLASS ON THE DISTAL END AND ON THE OCULAR SIDE
  • GOLD SOLDERED AT PROXIMAL AND DISTAL END. 100% LEAKPROOF AND MORE RESISTANT

• BRILLIANT ILLUMINATION AND CRYSTAL CLEAR RESOLUTION

• TRUE COLOUR REFLECTION AND REGULAR FOCUS ON THE WHOLE IMAGE

• OPTIMAL DEPTH OF FIELD

• STORZ- OLYMPUS- TEKNO / WOLF / ACMI ADAPTERS INCLUDED

• AUTOCLAVABLE; INCL.1 SEALING CAB AND 2 CLEANING BRUSHES

• MADE IN GERMANY

• CE, FDA

DOWNLOAD OUR COMPLETE PRODUCT CATALOGUE HERE

why choose
maxmorespine sytems?

Other endoscopic systems are challenged by difficulties in handling, inability to access and treat all pathology, ease of use, and versatility. The maxmorespine® system permits a safe, precise and efficient access to and removal of all herniations, particularly L5-S1.

More information

why choose
maxmorespine sytems?

Give us a call: +49 (0) 69 665588 00
or send us an e-mail:info@max-more.com

Go to contact page

Other systems